Battery testing machine for any rechargeable battery with-in the range of 0 - 5V system, capable of handling 0 - 20 amps for cycle testing to test the battery. RPE teams up with Neware to bring you a battery tester for all your battery testing needs.
This item takes 10 - 20 business days to ship to your location with instruction on how to connect please contact RPE for more information in regards to this product.
Specifications
- Input AC AC 110V ±10% / 50Hz
- Input power 1418 W
- Resolution AD:16bit;DA:16bit
- Input impendence ≥1MΩ
Voltage
- CV output range 0.025V~5V
- Min discharge voltage 2.5V
- Accuracy ± 0.1% of FS
- Stability ± 0.1% of FS
Current
- Output range/channel 0.1A~20A
- Accuracy ± 0.1% of FS
- CV cut-off current 0.04A
- Stability ± 0.1% of FS
Power
- Output power/channel 100 W
- Stability ± 0.2% of FS
Time
- Current rsponse time Max rising time:20ms
- Working step time ≤(365*24)h/step Time format-00:00:00.000(h、m、s、ms)
Data Record
Data record conditions
- Min data record interval:100ms
- Min voltage change:10mV
- Min current change:40mA
Frequency 10Hz
Charge
- Charge modes CC、CV、CCCV、CP、CCCV forbattery pack
- Cut-off condition Voltage、Current、Time、Capacity、-△V
Discharge
- Discharge modes CV、CP、CR
- Cut-off condition Voltage、Current、Time、Capacity、-△V
Pulse
- Charge CC、CP
- Discharge CC、CP
- Min pulse width 500ms
- Pulse counts Up to 32
- Chg and Dischg switch Supported
- Cut-off condition Voltage、Time
DCIR Supported
CH parallel If output current > 100A, then supported, in parallel mode pulse function is disabled
Cycles
- Max cycles 65535
- Max steps 254
- Nest 3
Protection
Power-off data protection
Safety protection
- Off-line operation mode
- User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc.
- Hardware protection Fooproof protection with hardware protection level IP20
- Channels feature Independent pairs of closed loop for constant
- Channels control mode Independent control
- Data acquisition method Kelvin connection
- Noise <85dB
- Database MySQL
- Communication TCP/IP
- Data Export Excel, TXT, PDF
- Disk space 500GB
- Leak current 0.005mA
- OS Windows 7
- Communication port Ethernet port
- Operation and storage environment requirement
Items Values
- Operation environment temperature
- 0℃~40℃ (When the temperature is 25±10℃, the
- accuracy error caused by temperature change is
- less than50ppm /℃)
- Storage environment temperature -10℃~50℃
- Operation environment humidity ≤70% RH(no moisture condensation)
- Storage environment humidity ≤80% RH(no moisture condensation)