Battery testing machine for any rechargeable battery with-in the range of 0-60V system, capable of handling 0-30 amps for cycle testing to test the battery. RPE teams up with Neware to bring you a battery tester for all your battery testing needs.
This item takes 10 - 20 business days to ship to your location with instruction on how to connect please contact RPE for more information in regards to this product.
Specification
- Input Power AC 110V ±10% / 50Hz
- resolution AD:16bit;DA:16bit
- Input Resistance ≥1MΩ
- Input Power 6278 W
Voltage
- Per Channel Voltage Range Charge:0.3V~60V;Discharge:0.3V~60V
- Accuracy ± 0.1% of range(Full-scale)
- Stability ± 0.1% of FS
- The minimum discharge voltage 3V
Current
- Per Channel Current Range Charge:0.1A~30A;Discharge:0.1A~30A
- Accuracy ± 0.1% of range(Full-scale)
- Stability ± 0.1% of FS
- Constant pressurecut-off current 0.04A
The Pulse Mode
- Charge Constant Current, Constant Power Mode
- Discharge Constant Current, Constant Power Mode
- The minimum pulsewidth 500ms
- The number of pulses A singlestep pulsework support 32 different pulse
- Charge and discharge switch in a row a step pulse work can realize continuous switching from charging to discharge
- As conditions Voltage, relative time
DCIR Test Support Custom Take DCIR Calculation
Power
- Per Channel Output Power 1200W
- Stability ± 0.2% of FS
Time
- Current Response Time The Current gets to 3A Hardware ResponseTime is 20ms
- Step Time Range
- 1min ≤Single Step Time Range≤365*24 h,
- Time Form Support 00:00:00(h、min、s)
Data Recording Condition
- Minimum time interval:100ms
- Minimum voltage interval:120mV
- Minimum current interval:40mA
- Record Frequency 10Hz
Charge
- Constant Current Charge、Constant Voltage Charge、
- Constant Current and Constant Voltage Charge、Constant Power charging
- End Conditon Voltage、Current、Relative Time、Capacity
Discharge
- Constant Current Discharge、Constant Power Discharge、
- constant-resistance discharge
- End Condition Voltage、Current、Relative Time、Capacity
Cycle
- Loop Measure Range 1~65535 times
- Max Steps Per Loop 254
Technical Specification
- Nested Loop Nested loop Function,Max Support 3 Layers
Protection Software Protection
- Power-down DataProtection
- With Functions Of Off-line Testing
- Setting Protection Condition,Setting Parameter:Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time
- Voltage and Current Testing Sample 4-wire connecting
- Channel Features
- Constant Current Source and Constant Voltage Sourcewith Independent
- pairs of Closed-loop Structure
- Channel Control Mode Channel Control Mode
- Database Using the MySQL database centralized management test data
- Noise <80dB
- Data Output EXCEL2003,2010、TXT
- Communication Interface Net port
- Per Unit Main Channels No. 8
- Server Disk Configuration 500G
- Leakage Current 0.06mA
- The Server Operating System Windows XP,Windows 7
- Communication Interface Nternet Access
Dimensions 24U(19”),600*600*1260 (mm)
Equipment Working Environment
- Project index Parameter index
- WorkingTemperature Range 0℃~40℃
- StorageTemperature Range -10℃~50℃
- Working Environment Relative Humidity Range ≤70% RH
- Storage Environment Relative Humidity Range ≤70% RH