20 Volt 6 Amp Battery Tester

by Neware
$3,700.00

Battery testing machine for any rechargeable battery with-in the range of 0 - 20V system, capable of handling 0 - 6 amps for cycle testing to test the battery. RPE teams up with Neware to bring you a battery tester for all your battery testing needs. 

This item takes 10 - 20 business days to ship to your location with instruction on how to connect please contact RPE for more information in regards to this product. 

Specifications 

  • Input AC AC 110V ±10% / 50Hz
  • Input power 1337 W
  • Resolution AD:16bit;DA:16bit
  • Input impendence ≥1MΩ

Voltage

  • CV output range 0.1V~20V
  • Min discharge voltage 2.5V
  • Accuracy ± 0.1% of FS
  • Stability ± 0.1% of FS

Current

  • Output range/channel 0.03A~6A
  • Accuracy ± 0.1% of FS
  • CV cut-off current 0.012A
  • Stability ± 0.1% of FS

Power

  • Output power/channel 120 W
  • Stability ± 0.2% of FS

Time

  • Current rsponse time Max rising time:20ms
  • Working step time ≤(365*24)h/step Time format-00:00:00.000(h、m、s、ms)

Data Record

Data record conditions

  • Min data record interval:100ms
  • Min voltage change:40mV
  • Min current change:12mA
  • Frequency 10Hz

Charge

  • Charge modes CC、CV、CCCV、CP、CCCV forbattery pack
  • Cut-off condition Voltage、Current、Time、Capacity、-△V

Discharge

  • Discharge modes CV、CP、CR
  • Cut-off condition Voltage、Current、Time、Capacity、-△V

Pulse

  • Charge CC、CP
  • Discharge CC、CP
  • Min pulse width 500ms
  • Pulse counts Up to 32
  • Chg and Dischg switch Supported
  • Cut-off condition Voltage、Time

DCIR Supported

CH parallelIf output current > 100A, then supported, in parallel mode pulse function is disabled

Cycles

  • Max cycles 65535
  • Max steps 254
  • Nest 3

 

Safety protection

  • Off-line operation mode
  • Power-off data protection
  • User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc.
  • Hardware protection Full proof protection with hardware protection level IP20

 

  1. Channels feature Independent pairs of closed loop for constant
  2. Channels control mode Independent control
  3. Data acquisition method Kelvin connection
  4. Noise <85dB
  5. Database MySQL
  6. Communication TCP/IP
  7. Data Export Excel, TXT, PDF
  8. Disk space 500GB
  9. Leak current 0.02mA
  10. OS Windows 7
  11. Communication port Ethernet port
  12. Operation and storage environment requirement

Items Values

  • Operation environment temperature
  • 0℃~40℃ (When the temperature is 25±10℃, the
  • accuracy error caused by temperature change is
  • less than50ppm /℃)
  • Storage environment temperature -10℃~50℃
  • Operation environment humidity ≤70% RH(no moisture condensation)
  • Storage environment humidity ≤80% RH(no moisture condensation)