Specification 

  • Input AC AC 110V ±10% / 50Hz
  • Input power 1033 W
  • Resolution AD:16bit;DA:16bit
  • Input impendence ≥1MΩ

Voltage

  • CV output range 0.075V~15V
  • Min discharge voltage 2.5V
  • Accuracy ± 0.1% of FS
  • Stability ± 0.1% of FS

Current

  • Output range/channel 0.03A~6A
  • Accuracy ± 0.1% of FS
  • CV cut-off current 0.012A
  • Stability ± 0.1% of FS

Power

  • Output power/channel 90 W
  • Stability ± 0.2% of FS

Time

  • Current rsponse time Max rising time:20ms
  • Working step time ≤(365*24)h/step Time format-00:00:00.000(h、m、s、ms)

Data Record

Data record conditions

  • Min data record interval:100ms
  • Min voltage change:30mV
  • Min current change:12mA
  • Frequency 10Hz

Charge

  • Charge modes CC、CV、CCCV、CP、CCCV forbattery pack
  • Cut-off condition Voltage、Current、Time、Capacity、-△V

Discharge

  • Discharge modes CV、CP、CR
  • Cut-off condition Voltage、Current、Time、Capacity、-△V

Pulse

  • Charge CC、CP
  • Discharge CC、CP
  • Min pulse width 500ms
  • Pulse counts Up to 32
  • Chg and Dischg switch Supported
  • Cut-off condition Voltage、Time

DCIR Supported

CH parallel If output current > 100A, then supported, in parallel mode pulse function is disabled

Cycles

  • Max cycles 65535
  • Max steps 254
  • Nest 3

Safety protection

  • Off-line operation mode
  • User-defined protection conditions, such as upper Power-off data protection
  • Protection and lower limited current/voltage, delay time, temperature, etc.
  • Hardware protection Fooproof protection with hardware protection level IP20
  • Power-off data protection
  1. Channels feature Independent pairs of closed loop for constant
  2. Channels control mode Independent control
  3. Data acquisition method Kelvin connection
  4. Noise <85dB
  5. Database MySQL
  6. Communication TCP/IP
  7. Data Export Excel, TXT, PDF
  8. Disk space 500GB
  9. Leak current 0.015mA
  10. OS Windows 7
  11. Communication port Ethernet port
  12. Operation and storage environment requirement

Items Values

  • Operation environment temperature
  • 0℃~40℃ (When the temperature is 25±10℃, the
  • accuracy error caused by temperature change is less than50ppm /℃)
  • Storage environment temperature -10℃~50℃
  • Operation environment humidity ≤70% RH(no moisture condensation)
  • Storage environment humidity ≤80% RH(no moisture condensation)