5 Volt 20 Amp Battery Tester

by Neware
$3,500.00

Battery testing machine for any rechargeable battery with-in the range of 0 - 5V system, capable of handling 0 - 20 amps for cycle testing to test the battery. RPE teams up with Neware to bring you a battery tester for all your battery testing needs. 

This item takes 10 - 20 business days to ship to your location with instruction on how to connect please contact RPE for more information in regards to this product.

Specifications 

  • Input AC AC 110V ±10% / 50Hz
  • Input power 1418 W
  • Resolution AD:16bit;DA:16bit
  • Input impendence ≥1MΩ

Voltage

  • CV output range 0.025V~5V
  • Min discharge voltage 2.5V
  • Accuracy ± 0.1% of FS
  • Stability ± 0.1% of FS

Current

  • Output range/channel 0.1A~20A
  • Accuracy ± 0.1% of FS
  • CV cut-off current 0.04A
  • Stability ± 0.1% of FS

Power

  • Output power/channel 100 W
  • Stability ± 0.2% of FS

Time

  • Current rsponse time Max rising time:20ms
  • Working step time ≤(365*24)h/step Time format-00:00:00.000(h、m、s、ms)

Data Record

Data record conditions

  • Min data record interval:100ms
  • Min voltage change:10mV
  • Min current change:40mA

Frequency 10Hz

Charge

  • Charge modes CC、CV、CCCV、CP、CCCV forbattery pack
  • Cut-off condition Voltage、Current、Time、Capacity、-△V

Discharge

  • Discharge modes CV、CP、CR
  • Cut-off condition Voltage、Current、Time、Capacity、-△V

Pulse

  • Charge CC、CP
  • Discharge CC、CP
  • Min pulse width 500ms
  • Pulse counts Up to 32
  • Chg and Dischg switch Supported
  • Cut-off condition Voltage、Time

DCIR Supported

CH parallel If output current > 100A, then supported, in parallel mode pulse function is disabled

Cycles

  • Max cycles 65535
  • Max steps 254
  • Nest 3

Protection

Power-off data protection

Safety protection

  • Off-line operation mode
  • User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc.
  • Hardware protection Fooproof protection with hardware protection level IP20
  1. Channels feature Independent pairs of closed loop for constant
  2. Channels control mode Independent control
  3. Data acquisition method Kelvin connection
  4. Noise <85dB
  5. Database MySQL
  6. Communication TCP/IP
  7. Data Export Excel, TXT, PDF
  8. Disk space 500GB
  9. Leak current 0.005mA
  10. OS Windows 7
  11. Communication port Ethernet port
  12. Operation and storage environment requirement

Items Values

  • Operation environment temperature
  • 0℃~40℃ (When the temperature is 25±10℃, the
  • accuracy error caused by temperature change is
  • less than50ppm /℃)
  • Storage environment temperature -10℃~50℃
  • Operation environment humidity ≤70% RH(no moisture condensation)
  • Storage environment humidity ≤80% RH(no moisture condensation)