5 Volt 5 Amp Battery Tester

by Neware
$8,750.00

Battery testing machine for any rechargeable battery with-in the range of 0 - 5V system, capable of handling 0 - 5 amps for cycle testing to test the battery. RPE teams up with Neware to bring you a battery tester for all your battery testing needs. 

This item takes 10 - 20 business days to ship to your location with instruction on how to connect please contact RPE for more information in regards to this product.

Specifications 

  • AC input AC 220V ±10% 50Hz / AC 110V ±10% 50Hz
  • Resolution AD:16bit;DA:16bit
  • Input impendence ≥ 500MΩ (power on), LC=100uA(power off)
  • Input power 500 w
  • Features 4 ranges, high acquisition frequency, high accuracy
  • Channels control mode Independent control

 

Voltage

  • Voltage output Charge:0.7 V~5V;Discharge:0.7 V~5V(0.5m data wire)
  • Lowest output voltage 0.7 V(0.5m data wire)

Accuracy ± 0.02% of FS

  • Stability ±0.005% of FS

 

Current

Current output ranges

  • Range 1: 0.1uA---150uA
  • Range 2:140uA---5mA
  • Range 3:4.5mA---150mA
  • Range 4: 140mA---5A

Accuracy

  • ± 0.02% of FS
  • Range 1: ± 30nA
  • Range 2:± 1uA
  • Range 3:± 30uA
  • Range 4: ± 1mA
  • Stability ±0.005% of FS

Power

  • Output power/CH 25W
  • Stability ± 0.01% of FS

 

Time

  • Current response time <= 100μS (10% to 90% or 90% to 10%);
  • Testing step time range >=10ms
  •  Data record conditions Time △t:>=1ms

Data record Data record conditions

  • Time △t:>=1ms
  • Voltage △U:>= 1mV
  • Current △I:>= 100nA
  • Frequency 1000Hz , Pulse

Charge

  • Modes CC, CCCV, CV, CP, CR
  • End conditions Voltage, Current, △t, Capacity, Energy, Power

Discharge

  • Modes CC, CP, CR, Pulse
  • End conditions Voltage, Current, △t, Capacity

Pulse

  • Charge CC, CP
  • Discharge CC, CP
  • Min. pulse width 400μs
  • Pulses counts Up to 16 changes in each pulse
  • End conditions Voltage, △t
  • DCIR Can be calculated by software

Cycle

  • Max cycles 65535
  • Max steps in each cycle 255
  • Max cycle nest 4

Protection Safety protection

  • Power-off data protection
  • Off-line operation mode
  • User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc.
  1. Data acquisition method Kelvin connection
  2. Database MySQL
  3. Data export Xls, txt
  4. Communication Ethernet
  5. Channels 8
  6. Dimensions 48*33*13(cm)
  7. Clamps 204 Air-plug, Polymer or alligator available
  8. Operating system Windows 7 for the best
  9. Operation and storage environment requirement

Items Values

  • Operation environment temperature
  • 0℃~40℃ (When the temperature is 25±10℃, the accuracy error caused by
  • temperature change is less than50ppm /℃)
  • Storage environment temperature -10℃~50℃
  • Operation environment humidity ≤70% RH(no moisture condensation)
  • Storage environment humidity ≤80% RH(no moisture condensation)